Displaying report 1-1 of 1.
Reports until 13:02, Thursday 08 August 2024
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 13:02, Thursday 08 August 2024 - last comment - 18:08, Thursday 08 August 2024(79513)
SRM, ZM6, OFI, OMC, OM2, OM3 (Mostly) In-vac Health Check TFs -- all look great (SRM Taken with Alignment Offsets ON)
J. Kissel

Took the opportunity to grab post-OFI-repair vent, in-vac transfer functions of the following HAM5 and HAM6 SUS. Of course, we're not at full observing-level vacuum, but most of the molecules are out of the chamber that would contribute to buoyancy, so the SUS are at the position they will be in observing-level vacuum.

Executive summary: I'm happy with all SUS that I measured -- including the two that were "interesting" and or touched during this vent -- SRM and OFI.
For the story about SRM, see LHO:79433.
And of course, the OFI had had optics replaced.
Several other SUS in HAM5 / 6 were not touched during the vent (aside from a few alignment sliders), so we didn't expect any degradation in performance and don't see any. These SUS are ready to resume observing gravitational waves!

Processed results will be posted as comments below.

Some relevant details of the status of the suspensions and their surroundings during the measurements.
Environment Status (Same for HAM5 and HAM6)
    ISI DAMPED
    HPI OFFLINE and mechanically locked
    VAC Pressure at 1e-5 Torr
 
Status of alignment offsets and coil driver switchable filter requested (CD) State.
    OPTIC   ON/OFF     Value (if on, [urad])     CD State
    SRM     ON          P/Y : +1663 / -3095      1, LP OFF
    ZM6     OFF         (n/a)                    Fixed in 2, LP ON
    OFI     OFF         (n/a)                    Fixed in 2, LP ON
    OMC     ON          P/Y : +340.5 / 0.0       1, LP OFF
    OM2     ON          P/Y : +716 / -1701       Fixed in 2, LP ON
    OM3     ON          P/Y : -1147 / +20        Fixed in 2, LP ON

File Names:
    SRM         HSTS/H1/SRM/SAGM1/Data/2024-08-08_1823_H1SUSSRM_M1_WhiteNoise*.xml
    ZM6         HXDS/H1/ZM6/SAGM1/Data/2024-08-08_1828_H1SUSZM6_M1_WhiteNoise*.xml
    OFI         OFIS/H1/OFI/SAGM1/Data/2024-08-08_1850_H1SUSOFI_M1_WhiteNoise*.xml
    OMC         OMCS/H1/OMC/SAGM1/Data/2024-08-08_1900_H1SUSOMC_M1_WhiteNoise*.xml
    OM2         HXDS/H1/OM2/SAGM1/Data/2024-08-08_1920_H1SUSOM2_M1_WhiteNoise*.xml
    OM3         HTTS/H1/OM3/SAGM1/Data/2024-08-08_1935_H1SUSOM3_M1_WhiteNoise*.xml
Comments related to this report
oli.patane@LIGO.ORG - 18:08, Thursday 08 August 2024 (79515)

SRM Results (regular, zoomed)

Found at $(sustrunk)/HSTS/Common/Data/allhstss_2024_08-08_H1SUSSRM_M1_PostOFIVentAirvVac_ALL*_TFs.pdf

ZM6 Results (regular, zoomed)

Found at $(sustrunk)/HXDS/Common/Data/allhxdss_2024-08-08_H1SUSZM6_InAirvVac_ALL*_TFs.pdf

OFI Results (regular, zoomed)

Found at $(sustrunk)/OFIS/Common/Data/allofiss_2024-08-08_H1SUSOFI_PreVentvPostInAirvInVac_ALL*_TFs.pdf

OMC Results (regular, zoomed)

Found at $(sustrunk)/OMCS/Common/Data/allomcss_2024-08-08_H1SUSOMC_PreVentvPost_ALL*_TFs.pdf

OM2 Results (regular, zoomed)

Found at $(sustrunk)/HXDS/Common/Data/allhxdss_2024-08-08_H1SUSOM2_Vac_ALL*_TFs.pdf

OM3 Results (regular, zoomed)

Found at $(sustrunk)/HTTS/Common/Data/allhttss_2024-08-08_OM3_H1SUSHTTS_PostVentInAirvVac_ALL*_TFs.pdf

Non-image files attached to this comment
Displaying report 1-1 of 1.