TITLE: 08/16 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: None
SHIFT SUMMARY: Got the ion pumps pumping today, so the pressure has gone down quite a bit. Also did a quick check of AS_C and the fast shutter using single bounce (79575). The IMC is LOCKED, and ITMs are MISALIGNED.
LOG:
14:30 In Corrective maintanence, IMC in OFFLINE
- I adjusted the OPTICALIGN OFFSET values for MC1,MC2, and MC3 until the driftmon values were back to what they had been yesterday before the computer crash. Then I took IMC_LOCK to LOCKED and it caught easily.
16:30 Ion pumps turned on
18:00 - 19:00 Single bounce measurement
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
16:32 | VAC | Gerardo, Travis | LVEA | n | Possibly turning on ion pumps | 17:02 |
16:55 | SUS | RyanC | CR | N | OPLEV charge measurements, EX & EY | 18:23 |
17:03 | Betsy | LVEA | n | Going around HAM7 (in @ 16:50) | 17:03 | |
18:21 | VAC | Gerardo, Fil | MY | n | Putting down cable and picking up cable (allegedly different cables) | 18:55 |
19:05 | VAC | Gerardo, Travis | LVEA | n | Adding another ion pump | 19:13 |
20:51 | TOUR | Genevieve+1 | LVEA | n | tour | 21:41 |
22:25 | VAC | Gerardo | EY | n | Taking a photo | 22:57 |
22:57 | VAC | Gerardo | LVEA | n | A check before he leaves | 23:57 |