In-Lock SUS Charge Measurements ITMX Mystery Solved

Camilla, Oli

We looked into the weird results we were seeing in the ITMX In-Lock SUS charge measurements. The coherence when the bias is on for both the bias and length drives is always good, but the coherences are bad (usually below 0.09) for both bias and length drives when the excitations run with the bias off.

I compared the differences in the coherence value outputs in the python script versus the matlab script(screenshot), and although the values are calculated slightly differently and are not exactly the same, they are resonably close enough that we can say that there is not an issue with how we are calculating the coherences.

Next, we used ndscope to look at the latest excitations and measurements from July 09th (ndscope-bais on, ndscope-bias off). Plotting L3_LOCK_BIAS_OUTPUT, L3_DRIVEALIGN_L2L_OUTPUT, L3_LVESDAMON_UL_OUT_DQ, and L3_ESDAMON_DC_OUT_DQ for both ITMX and ITMY, if there was an issue with the excitations not going through, we would expect to see nothing on the ESDAMON and LVESDAMON channels, but we do see them on ITMX.

We were still confused as to why we would see the excitations go through the ESDAMON channels but still have such low coherence, so we compared the ITMX measurements to ITMY on dtt for the July 09th measurements looking at how each excitation showed up in DARM and what the coherence was. When the bias was on, both the bias drive and Length drive measurements look as we expect, with the drive in their respective channels, a peak seen in DARM at that frequency, and a coherence of 1 at that frequency(bias_drive_bias_on, length_drive_bias_on). However, in the comparisons with the bias off, we can see the excitations in their channels for both ITMX and ITMY, but while ITMY has the peak in DARM like the bias on measurements, ITMX is missing this peak in DARM(bias_drive_bias_off, length_drive_bias_off). The coherence between DARM and the excitation channel is also not 1 on ITMX.

We showed these results to Sheila and she said that these results for ITMX with the bias off make sense if there is no charge built up on the ITM, which would be the first time this has been the case! So there are no issues with the excitations or script thankfully.

We will be making changes to the analysis script to still run the analysis even if the coherence is low, and will be adding a note explaining what that means.

Images attached to this report
Comments related to this report
vladimir.bossilkov@LIGO.ORG - 10:14, Wednesday 21 August 2024 (79626)

Hey LHO, the in lock charge measurement script is another script, other than A2L scripts and calibration scripts, that I overhauled last year due to my deep dissatisfaction with the existing code.

I'll point you to the aLog when I ran it: [68310].

Among the huge amount of behaviors that I correct I implemented many lessons I learned in implementing simuLines for LHO: your DARM units are a very small number and you must explicitly cast DARM data to np.float64 in order to have the TFs and coherences (in particular coherences) calculate correctly. I've had to repeat this lesson to lat least 4 people writing code for LHO now in the calibration group because it trips up people again and again and it is not an obvious thing to do, and something I solved through sheer brute force (took Louis a lot to convince since he initially refused to believe it).

In particular inside the ''digestData" function of the "/ligo/svncommon/SusSVN/sus/trunk/QUAD/L1/Common/Scripts/InLockChargeMeasurements/process_single_measurement.py" you will see me casting the gwpy data to float64 on lines 50 and 51; followed by some sampling rate tricks to get coherence to calculate correctly with gwpy's coherence call as well as gwpy handles average_fft calls.

Hope it helps!

camilla.compton@LIGO.ORG - 16:47, Friday 23 August 2024 (79672)

Thanks Vlad, we'll have a look at that.

While looking at these  measurements we realized that we were not using the same bias setting for all the quads (ITMY around half bias). We want to change this using the attached code but first will run the charge measurements to directly compare before and post vent.

Non-image files attached to this comment