Vent Recovery Commissioning Part 2/?

[Ryan S, Corey, Camilla, TJ, Elenna]

Quick, must be fixed ASAP summary: something is wrong with ALS Y. The WFS are not engaging when they should. DOF2 seems to be bad right now, and the camera offsets are also not good. Guardian does not notice the WFS are not engaging. Do not trust the green camera offsets on the Y arm.

Ryan S brought the IFO to DC readout successfully, and began damping violin modes. Some noisy peaks are evident, probably due to pumps that are still running and/or the HAM5/7 relay tube gate valve is still closed.

I set SRC1 P and Y offsets and engaged the loops. SRC1 P offset = -0.538 and SRC1 Y offset = 1.327

These offsets keep us in a good place for the SRM, and then I can walk SR2 to converge the SRC2 loop.

This worked for pitch, and I was just about to engage SRC2 pitch when there was a lockloss due to HAM6 motion. Both the vacuum team and Camilla and TJ were around that area for various activities, potentially causing the lockloss.

After TJ and Camilla aligned the OMC trans camera, we ran initial alignment (trying to lock DRMI failed because the alignment was very poor).

Initial alignment failure:

I had us give up and run a manual initial alignment without using the green cameras.

It appears that even in "Locked slow wfs" the ALS Y WFS do not turn on, but it's somehow not a problem in the guardian because the error signals are pretty well converged already? Something is going wrong with the ALS Y WFS. Trending back it seems that the ALS Y WFS did not run at all today, and we didn't seem to notice!

In order to properly run the WFS, I have to take the ALS Y guardian to "locked slow ETM TMS WFS" and then "force" the autocentering trigger in order to turn on the WFS. Then I can let the guardian move on to offloading.

Additionally, ALS Y DOF 2 is taking the Y arm in a bad direction again after it converges the alignment in green locking. Once I force on the Y arm WFS, I turn off the DOF2 signals and that keeps the Y arm stable through the next locking steps.

To get the SRC ASC on:

Indeed now that we are in full good alignment with ASC engaged, the ALS Y green is no longer locked on a 00 mode, which means that the camera offsets from earlier are maybe incorrect. However, I could not get the ALS Y to lock on the 00 beam in order to reset the offsets. First, I tried moving the green QPD offset sliders around, then I tried very slowly moving the TMS in 0.1 urad steps. All I can get on the camera is this.

However, I did another set of the ALS X green references (very minor change), with the SDF screenshot attached. The ITMX CAM values were still good, so I didn't change them.

Everything else executed well: power up, low noise transitions. I skipped over "inject squeezing" since we don't have the valves open for the FC yet. We have arrived in OMC whitening, where the guardian is holding us to damp the violins.

DARM is very noisy, probably due to whatever vacuum pumps are still running and any extra noise due to the relay tube being closed. Most calibration lines have no SNR due to the high noise.

Major problem to solve is the ALS Y alignment and camera offsets, but locking has succeeded and we are almost back to nominal!