sheila.dwyer@LIGO.ORG - posted 13:28, Friday 23 August 2024 (79668)
increased COMM offset to have arms further off resonance during DRMI acquisition

I've often been increasing the COMM offset when I see arm cavity flashes during DRMI acquisition for a few months.  I think based on anecdotal evidence that this helps DRMI lock faster, and it hasn't caused any issue with the CARM handoffs in the times I've done it manually. So Ryan, Elenna and I have just now added this offset into the guardian (ISC_LOCK ARMS_OFF_RESONANCE offset is changed from -100o to -2000). 