naoki.aritomi@LIGO.ORG - posted 11:29, Thursday 22 August 2024 - last comment - 13:48, Friday 23 August 2024(79643)
SQZ is ready for IFO

After HAM7/FC GVs were open this morning, I aligned FC1/2 and FC GR is locked. FC GR trans is ~110, which is reasonable. 

I measured NLG following 76542. The measured NLG is 16 (0.247/0.0154=16), which is a bit lower than the last measurement in 78000. The OPO temperature is very different from before as shown in the attached SDF.

Images attached to this report
Comments related to this report
naoki.aritomi@LIGO.ORG - 13:48, Friday 23 August 2024 (79669)

I measured NLG again. The measured NLG is 17 (0.0041/0.00024=17). This is consistent with previous measurement and OPO temperature is closer to the previous value as shown in the attachment.