Stuck At ADS TO CAMERAS Again

H1 is currently stuck at ADS TO CAMERAS (same as last night); see attached screenshot.

CAMERA SERVO node has messages of:

"ASC-CAM_PIT1 (& YAW1)_INMON is stuck!  Do Not Advance!"

Will do some searching to see what the issue is. 

NOTE:  Sheila's alog that there was mention of PIT1 being updated.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:06, Saturday 24 August 2024 (79686)CDS

Ryan S--messaged me about the issue being the BS Camera being down (similar to alog 79648 on Thursday), so I just contacted Dave and he will be bringing this BS camera back up.

corey.gray@LIGO.ORG - 11:12, Saturday 24 August 2024 (79687)

As soon as Dave broght the camera back, I reselected CAMERA SERVO ON (for CAMERA_SERVO node) and this unstalled the node, and had ISC LOCK get us to NLN within a minute.....but of course, PI24 immediately started to ring up!  (But it looked like the SUS PI node damped it down).