Displaying report 1-1 of 1.
Reports until 13:50, Monday 26 August 2024
H1 PSL
anthony.sanchez@LIGO.ORG - posted 13:50, Monday 26 August 2024 (79718)
PSL Status Report - Weekly

FAMIS 26290


Laser Status:
    NPRO output power is 1.831W (nominal ~2W)
    AMP1 output power is 64.55W (nominal ~70W)
    AMP2 output power is 137.1W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 6 days, 23 hr 49 minutes
    Reflected power = 21.13W
    Transmitted power = 105.6W
    PowerSum = 126.7W

FSS:
    It has been locked for 0 days 1 hr and 37 min
    TPD[V] = 0.6479V

ISS:
    The diffracted power is around 1.9%
    Last saturation event was 0 days 1 hours and 37 minutes ago


Possible Issues:
    AMP1 power is low
    PMC reflected power is high
    FSS TPD is low
    ISS diffracted power is low

Displaying report 1-1 of 1.