Since it hasn't been done since before the vent, and the output of the PMC has continued to slowly drop, before locking today I calibrated the PSL rotation stage following the steps in alog79596.
The measurement file, new calibration fit, and screenshot of accepting SDFs are all attached.
| Power in (W) | D | B (Minimum power angle) | C (Minimum power) | |
| Old Values | 97.882 | 1.990 | -24.818 | 0.000 |
| New Values | 94.642 | 1.990 | -24.794 |
0.000 |