Displaying report 1-1 of 1.
Reports until 12:51, Tuesday 27 August 2024
H1 ISC
sheila.dwyer@LIGO.ORG - posted 12:51, Tuesday 27 August 2024 (79740)
added more DOFs back to DRMI ASC

TJ, Sheila

TJ is having difficulty locking in the high winds this afternoon.  We've been running without DRMI ASC other than the BS, so that operators have to manually adjust PRM and SRM sometimes.  This afternoon we added back in INP1, PR1 and PRC2 loops, but left SRC ASC off.  This seems to be helping with POP18, although the operators may still need to adjust SRM by hand.

Displaying report 1-1 of 1.