Displaying report 1-1 of 1.
Reports until 17:34, Tuesday 27 August 2024
H1 ISC
naoki.aritomi@LIGO.ORG - posted 17:34, Tuesday 27 August 2024 (79753)
PI ringup at 10.428 kHz

In the last lock, PI31 at 10.428 kHz rang up as shown in the first attachment. Although it was damped by SUS_PI guardian, PI31 RMSMON reached close to 2000. The frequency of this PI is 10427.67 Hz as shown in the second attachment. This is within the input bandpass filter (425-431 Hz after downconversion by 10kHz). I increased damping gain for PI31 from 1000 to 10000 in SUS_PI guardian.

EDIT: This gain increase was too much. I reverted the damping gain to 1000 in SUS_PI guardian.

Images attached to this report
Displaying report 1-1 of 1.