Displaying report 1-1 of 1.
Reports until 16:23, Saturday 31 August 2024
H1 General (Lockloss)
ryan.short@LIGO.ORG - posted 16:23, Saturday 31 August 2024 - last comment - 17:21, Saturday 31 August 2024(79844)
Lockloss @ 23:14 UTC

Lockloss @ 23:14 UTC - link to lockloss tool

No obvious cause; maybe some small motion by ETMX immediately before lockloss like we've seen before, but it's much smaller than usual.

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 17:21, Saturday 31 August 2024 (79847)CAL

H1 back to observing at 00:14 UTC.

To go to observing, I reverted the SDF diff on the susetmx model for the new ETMX drivealign L2L gain provided by Francisco's script (screenshot attached; see alog79841). This had not been updated in Guardian-space, so it was set to the previous setpoint during TRANSITION_FROM_ETMX. I've updated the gain to 191.711514 in lscparams.py, saved it, and loaded ISC_LOCK.

Images attached to this comment
Displaying report 1-1 of 1.