H1 Back to Observing - SQZ SHG Fiber Launch Power Reduced

Once H1 relocked to NLN this evening, I noticed it didn't look like FDS was being injected, and then I saw a notification on the SQZ_OPO_LR Guardian node saying, "too much pump light into fiber? Adjust the half wave plate." Tony pointed me to alog78696 where he needed to make a similar adjustment. I attempted to follow that procedure to lower the green SHG launch power below 35 (threshold in Guardian) from where it was around 36.6 using the half-wave plate, but I was unsuccessful. Moving the 'SQZ SHG FIBR HWP/QWP' picomotor (motor 3) made the launch power signal shake as the wave plate moved, but the level did not change. I called Naoki for assistance and he corrected me, saying that I should have been moving the half-wave plate before the launch and rejected PDs instead of the one after them; making the correct motor be 'SQZ Laser FIBR HWP/SHG GR power' (motor 2). He made the adjustments necessary to bring the launch power down and rejected power up, then used Guardian to inject squeezing without issue.