john.worden@LIGO.ORG - posted 10:00, Friday 04 October 2013 - last comment - 12:06, Friday 04 October 2013(7990)
LVEA Purge Air Compressor Kobelco

The purge air system is up and running again. The Kobelco air compressor had shut down on an over temperature alarm which has been determined to be an open circuit RTD.

As a temporary fix a 1k resistor has been installed in place of the RTD.

 

Temps now after one hour of run time are:

 

1st air discharge - 287F

2nd air suction - 85 F

2nd air discharge - measured at 210F Front panel says 65F(1k resistor)

lube oil - 104F

Comments related to this report
john.worden@LIGO.ORG - 12:06, Friday 04 October 2013 (7994)

Temperatures remain the same at 12:00