Displaying report 1-1 of 1.
Reports until 09:49, Thursday 05 September 2024
H1 CDS
david.barker@LIGO.ORG - posted 09:49, Thursday 05 September 2024 (79920)
O4 IPC error summary

Here is a summary of the 4 spontaneous IPC errors we have seen during the O4 run so far.

alog date details
79913 02:08:03 Thu 05sep2024 long-range-dolphin h1susetmx sender @
74665 11:09:47 Thu 07dec2023 CS dolphin h1lsc0 sender *
74365 05:22:13 Tue 21nov2023 CS dolphin h1lsc0 sender *
73584 18:47:05 Wed 18oct2023 long-range-dolphin h1susetmx sender @

Note that both the * and the @ events are identical pairs of events.

The fact that h1susetmx had todays issue back on Oct 2023 rules out the recent addition of the new LIGO-28AO32 DAC card as being a possible problem.