Closes FAMIS#26493, last checked 79438
T240 (channels averaged between 2024-09-06 22:13:59 - 22:14:09UTC)
There are 14 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.705 [V]
ETMX T240 2 DOF Y/V = -0.571 [V]
ETMX T240 2 DOF Z/W = -0.543 [V]
ITMX T240 1 DOF X/U = -1.471 [V]
ITMX T240 1 DOF Y/V = 0.317 [V]
ITMX T240 1 DOF Z/W = 0.42 [V]
ITMX T240 3 DOF X/U = -1.535 [V]
ITMY T240 3 DOF X/U = -0.753 [V]
ITMY T240 3 DOF Z/W = -1.878 [V]
BS T240 1 DOF Y/V = -0.404 [V]
BS T240 3 DOF Y/V = -0.321 [V]
BS T240 3 DOF Z/W = -0.504 [V]
HAM8 1 DOF Y/V = -0.512 [V]
HAM8 1 DOF Z/W = -0.824 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.108 [V]
ETMX T240 1 DOF Y/V = -0.111 [V]
ETMX T240 1 DOF Z/W = -0.191 [V]
ETMX T240 3 DOF X/U = -0.133 [V]
ETMX T240 3 DOF Y/V = -0.201 [V]
ETMX T240 3 DOF Z/W = -0.104 [V]
ETMY T240 1 DOF X/U = 0.013 [V]
ETMY T240 1 DOF Y/V = 0.097 [V]
ETMY T240 1 DOF Z/W = 0.162 [V]
ETMY T240 2 DOF X/U = -0.094 [V]
ETMY T240 2 DOF Y/V = 0.167 [V]
ETMY T240 2 DOF Z/W = 0.039 [V]
ETMY T240 3 DOF X/U = 0.175 [V]
ETMY T240 3 DOF Y/V = 0.036 [V]
ETMY T240 3 DOF Z/W = 0.096 [V]
ITMX T240 2 DOF X/U = 0.121 [V]
ITMX T240 2 DOF Y/V = 0.24 [V]
ITMX T240 2 DOF Z/W = 0.204 [V]
ITMX T240 3 DOF Y/V = 0.106 [V]
ITMX T240 3 DOF Z/W = 0.108 [V]
ITMY T240 1 DOF X/U = 0.05 [V]
ITMY T240 1 DOF Y/V = 0.057 [V]
ITMY T240 1 DOF Z/W = -0.059 [V]
ITMY T240 2 DOF X/U = 0.044 [V]
ITMY T240 2 DOF Y/V = 0.193 [V]
ITMY T240 2 DOF Z/W = 0.055 [V]
ITMY T240 3 DOF Y/V = 0.037 [V]
BS T240 1 DOF X/U = -0.179 [V]
BS T240 1 DOF Z/W = 0.082 [V]
BS T240 2 DOF X/U = -0.104 [V]
BS T240 2 DOF Y/V = 0.004 [V]
BS T240 2 DOF Z/W = -0.133 [V]
BS T240 3 DOF X/U = -0.211 [V]
HAM8 1 DOF X/U = -0.279 [V]
STS (channels averaged between 2024-09-06 22:21:52 - 22:22:02UTC)
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.402 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.521 [V]
STS A DOF Y/V = -0.829 [V]
STS A DOF Z/W = -0.536 [V]
STS B DOF X/U = 0.335 [V]
STS B DOF Y/V = 0.945 [V]
STS B DOF Z/W = -0.448 [V]
STS C DOF X/U = -0.764 [V]
STS C DOF Y/V = 0.766 [V]
STS C DOF Z/W = 0.563 [V]
STS EX DOF X/U = -0.17 [V]
STS EX DOF Y/V = -0.038 [V]
STS EX DOF Z/W = 0.075 [V]
STS EY DOF Y/V = 0.005 [V]
STS EY DOF Z/W = 1.225 [V]
STS FC DOF X/U = 0.24 [V]
STS FC DOF Y/V = -1.056 [V]
STS FC DOF Z/W = 0.622 [V]