Sheila, Louis, Francisco
Following LHO:80044, we measured ASC-DHARD_P(Y) for different ASC-AS_A_DC_YAW_OFFSET and found the loswet values of DHARD_Y at an offset of -0.05.
The "DTT_AS_A_*.png"s show the outputs of DHARD_DARM_240912 when changing AS_A_DC_OFFSET with a reference trace for when the offset was nominal (ASC-AS_A_DC_YAW_OFFSET = -0.15). Each trace has a marker at the two highest peaks in the ASC-DHARD power spectrum (the middle plot on the left). DTT_AS_A_neg0_05 shows the lowest value in the power spectrum compared to DTT_AS_A_neg0_10, while preserving coherence (lowest-left) and phase values (middle-rigt), compared to DTT_AS_A_0. AS_A_NDSCOPE corroborate on the times at which these measurements were done and the values for AS_A offset.
Confirming that the four TFs traces corresponding to reports
were all done under a thermalized interferometer.