J. Kissel Following up on the initial installation of the Online Detector Characterization channel for Input Mode Cleaner control system (see LHO aLOG 7894), I've cleaned things up further by - fixing the bit-bug that was inherent to the CTRLON bit (BIT 1), - added a few more EPICs records to make - calibration of the sum signals and power ratios possible and - the bit generation a little more clear and useful, - added negative space, notes, and clarifying colors to the slightly-complex bit-logic chain - spiffing up the screen to Izumi level. All bits, even up to the summary bit level, are now regularly green. This channel (H1:IMC-ODC_CHANNEL_OUT_DQ) should be ready for DetCharian DataAnalystic consumption. I attach new screen shots of the bits (pun intended) I've changed -- just the ODC block in the front-end model, and the screen. Still to-do, but not imperative for the functionality of the channel: - Get calibration factors for - All ASC error signals, H1:IMC-DOF[1,2,3,4]_[P/Y]_IN1, in [ct/urad] - H1:IMC-PWR_IN, the broad-band PD on PSL periscope in [ct/W] - H1:IMC-ODC_MC2_TRANS_SUM, the DC sum signal for MC2 transmitted light QPD in [ct/W] - H1:IMC-ODC_IM4_TRANS_SUM, the DC sum signal for MC2 transmitted light QPD in [ct/W] - Expected power ratio between PWR_IN and each transmitted sum in [W/W]. and install them in the available ODC EPICs records. - Fill out all the EPICs string records explaining each of the bits (though I tried to make the corresponding, EPICs channels {that are redundant with the ODC bitword itself BTW...} have names which are clear-ish). As of this log, new versions of /opt/rtcds/userapps/release/asc/h1/models/h1ascimc.mdl /opt/rtcds/userapps/release/ioo/common/medm/IMC_CUST_ODC.adl /opt/rtcds/userapps/release/asc/h1/burtfiles/h1ascimc_safe.snap have been committed to the userapps repo.