20:53 UTC lockloss
There were HAM3 CPS glitches on verbal before the LL, and PRM was the first saturating suspension from the LL tool.
Another CPS glitch tripped the HAM3 ISI
All of the glitches are on the H2 & V2 sensor, which I believe have their own rack, corner 1 & 3 are on the other rack. I've asked Ryan to go and power cycle the CPS electronics are the rack in the CER. We'll see if that fixes the issue.
I called Jim who advised I go to the CER and power cycle the HAM3 ISI interace chassic CPS power as we were seeing the glitches in H2 and V2, I did this which has fixed the issue (for now at least).
22:46 UTC Observing