Reports until 14:04, Sunday 22 September 2024
H1 General (Lockloss, SEI)
ryan.crouch@LIGO.ORG - posted 14:04, Sunday 22 September 2024 - last comment - 15:46, Sunday 22 September 2024(80232)
Lockloss

20:53 UTC lockloss

There were HAM3 CPS glitches on verbal before the LL, and PRM was the first saturating suspension from the LL tool.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 14:08, Sunday 22 September 2024 (80233)SEI

Another CPS glitch tripped the HAM3 ISI

Images attached to this comment
jim.warner@LIGO.ORG - 14:29, Sunday 22 September 2024 (80234)

All of the glitches are on the H2 & V2 sensor, which I believe have their own rack, corner 1 & 3 are on the other rack. I've asked Ryan to go and power cycle the CPS electronics are the rack in the CER. We'll see if that fixes the issue.

ryan.crouch@LIGO.ORG - 14:41, Sunday 22 September 2024 (80235)CDS, SEI

I called Jim who advised I go to the CER and power cycle the HAM3 ISI interace chassic CPS power as we were seeing the glitches in H2 and V2, I did this which has fixed the issue (for now at least).

ryan.crouch@LIGO.ORG - 15:46, Sunday 22 September 2024 (80237)

22:46 UTC Observing