Reports until 09:11, Saturday 28 September 2024
H1 PSL
ryan.short@LIGO.ORG - posted 09:11, Saturday 28 September 2024 (80343)
PSL Status Report - Weekly

FAMIS 26301

Laser Status:
    NPRO output power is 1.828W (nominal ~2W)
    AMP1 output power is 64.52W (nominal ~70W)
    AMP2 output power is 136.7W (nominal 135-140W)
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 0 days, 11 hr 34 minutes
    Reflected power = 22.33W
    Transmitted power = 104.0W
    PowerSum = 126.3W

FSS:
    It has been locked for 0 days 1 hr and 1 min
    TPD[V] = 0.7807V

ISS:
    The diffracted power is around 2.4%
    Last saturation event was 0 days 1 hours and 2 minutes ago


Possible Issues: (both are known)
    AMP1 power is low
    PMC reflected power is high