(Rich, Stefan) We installed jumpers in the coil drivers (D1100117) to permanently enable input on/off switch and the run switch. The affected the following coil driver serial numbers: S1106044 (RM1), S1200612 (RM2), S1106043 (OM1), S1200608 (OM2), S1200614 (OM3) For proper operation H1:ASC-RM2_BIO_M1_STATEREQ needs to be set to 2, and the anti-dewhitening filters need to be in FM6 of the H1:ASC-RM?_M1_COILOUTF_?? filter modules. (FM1 is reserved for the sim-dewhitenig filter.)