Displaying report 1-1 of 1.
Reports until 10:09, Monday 07 October 2024
H1 SQZ
camilla.compton@LIGO.ORG - posted 10:09, Monday 07 October 2024 - last comment - 12:25, Thursday 10 October 2024(80506)
SQZ ASC turned on using AS42 on ZM4/6

Sheila, Camilla.

New SQZ ASC using AS42 signals with feedback to ZM4 and ZM6 tested and implemented.  We still need to watch that this can keep a good SQZ alignment during thermalization. In O4a we used a SQZ ASC with  ZM5/6, we have not had a SQZ ASC for the majority of O4b.

Prep to improve SQZ:

Testing ASC from 80373:

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 17:16, Monday 07 October 2024 (80519)OpsInfo

In the first 20 minutes of the lock, the SQZ ASC appears to be working well, plot.

Note to operator team: if the squeezing gets really bad, you should be able to use the SQZ Overview > IFO ASC (black linked button) > "!graceful clear history" script to turn off the SQZ ASC. Then change /opt/rtcds/userapps/release/sqz/h1/guardian/sqzparams.py use_ifo_as42_asc to False and go though NO_SQZEEZING then FREQ_DEP_SQUEEZING in SQZ_MANAGER and accept the sdfs for not using SQZ ASC. If SQZ still looks bad, put ZM4/6 osems (H1:SUS-ZM4/6_M1_DAMP_P/Y_INMON) back to when squeezing was last good and if needed run scan sqz alignment and scan sqz angle with SQZ_MANAGER.

Images attached to this comment
camilla.compton@LIGO.ORG - 09:37, Tuesday 08 October 2024 (80534)

Sheila moved the  "0.01:0" integrators from the ASC_POS/ANG_P/Y filters into the ZM4/5/6_M1_LOCK_P/Y filter banks.

This will allow us to more easily adjust the ASC gains and to use the guardian ZM offload states. We turned them on on ZM4/6. Edited OFFLOAD_SQZ_ASC to offload for ZM4,5,6. And tested by putting an offset on ZM4.  We put ZM4/6 back to positions they were in in lock via the osesms. SDFs for filters accepted. I removed the "!offload AS42" button from the SQZ > IFO ASC screen (liked to sqz/h1/scripts/ASC/offload_IFO_AS42_ASC.py) as it caused a lockloss yesterday. 

Images attached to this comment
camilla.compton@LIGO.ORG - 14:10, Wednesday 09 October 2024 (80570)

Oli tested the SQZ_MANAGER OFFLOAD_SQZ_ASC guardian state today and it worked well.  We still need to make the state request-able. 

camilla.compton@LIGO.ORG - 12:25, Thursday 10 October 2024 (80594)

ASC now turns off before  SCAN_SQZANG_FDS/FIS and SCAN_ALIGNMENT_FDS/FIS. It wil check if the ASC is on via H1:SQZ-ASC_WFS_SWITCH and turn the asc off before scanning alignment or angle.

We changed the paths so that to get from SCAN_SQZANG_FDS/FIS and SCAN_ALIGNMENT_FDS/FIS back to squeezing, the guardian will go though SQZ_ASC_FDS/FIS to turn back on ASC afterwards.