Displaying report 1-1 of 1.
Reports until 16:01, Tuesday 08 October 2024
H1 General
oli.patane@LIGO.ORG - posted 16:01, Tuesday 08 October 2024 (80549)
Ops Day Shift End

TITLE: 10/08 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY:  Currently relocking and at MAX_POWER . We took a few extra hours after the normal maintenance period to continue troubleshooting the PSL issues, but it didn't come up with much.
When I took SEI_ENV to MAINTENANCE we lost lock (most likely due to increased ground motion from septic tank truck + MAINTENANCE mode switch)


LOG:

14:30 Locked for 3 hours and running magnetic injections
14:40 Injections done, back to Observing
14:45 Out of Observing, starting In-Lock SUS Charge measurements
15:10 Took SEI_ENV to MAINTENANCE
15:10 Lockloss due to ground motion while in MAINTENANCE

15:28 ISC_LOCK to IDLE

21:46 Sensor correction turned back on
21:52 Started manual initial alignment
22:29 Started relocking                                                                                                                                 

Start Time System Name Location Lazer_Haz Task Time End
14:57 FAC Chris H2/CP1 n Moving snorkel lift to CP1 15:28
14:42   Christina MX, MY n Inventory for 3IFO 15:56
15:12 FAC Kim, Karen, Patty FCETube n Tech clean 18:23
15:18 VAC Jordan FCETube n Installing pressure gauge and closing gate valves 20:03
15:21 EE Fil Beir Garden, CER n Prepping for seismometer 17:21
15:21   Betsy LVEA n O5 cabling tasks 15:33
15:36 SUS RyanC CR N OPLEV charge measurements, ETMs 16:54
15:54   Betsy OptLab n   16:54
15:56   Christina LVEA n Inventory walk around 17:21
15:00 FAC Septic tank vendor sitewide n Pumping tanks 16:13
16:17 FAC Tyler LVEA n Looking for forklift 16:23
16:29 ISI Jim CER n Power cycling ITMX ISI 17:07
16:40   Camilla LVEA n Looking at arms 18:27
16:45 EE Fernando MSR n Check ISC computer 22:42
16:54 tour Cassidy and Austin LVEA n tour 17:33
17:11 CDS Erik EX n Power cycling gps receiver 17:57
16:00 FAC Chris, Eric Opticslab n Taking apart fume hood 17:29
17:37   Betsy LVEA n Looking at things with Camilla 18:23
17:58 ISI Jim LVEA n Moving stuff 18:08
18:10 ISI Jim LVEA n Checking problem out 18:55
18:24   Christina Outside receiving n Throwing away stuff 18:52
18:29 CDS Erik EX n Taking out gps receiver 18:55
19:06   Tony LVEA n sweep 19:23
19:20 PSL Sheila, Rick LVEA n Testing stuff with NPRO 19:23
19:30 VAC Janos FCETube n gate values 20:03
19:35 FAC Karen Pre-VacPrep n Tech clean 20:16
19:43 CDS Erik EX n Replacing receiver 20:12
20:25 PSL Sheila, Rick LVEA n Unplug another cable for PSL issue 20:35
20:50   Camilla LVEA n Grabbing beamsplitters 21:17
21:26 PSL Sheila & Rick LVEA PSL Racks N Re-seating the DB cables and Barrel conectors. 21:33

 