Displaying report 1-1 of 1.
Reports until 08:30, Thursday 10 October 2024
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 08:30, Thursday 10 October 2024 - last comment - 09:01, Thursday 10 October 2024(80588)
Lockloss

Lockloss @ 10/10 15:29UTC during Commisioning

Comments related to this report
ryan.short@LIGO.ORG - 09:01, Thursday 10 October 2024 (80591)

Seems that the IMC lost lock here (correctly tagged "IMC" by the lockloss tool, see short-term trend), but I'm not convinced in this case it was due to the FSS. The last FSS glitch happened ~4 seconds before the IMC lost lock and there weren't many happening frequently before that (see longer-term trend).

Images attached to this comment