I added a tag to the locklost tool to tag "IMC" if the IMC looses lock within 50ms of the AS_A channel seeing the lockloss: MR !139. This will work for all future locklosses.
I then ran just the refined time plugin on all NLN locklosses from the emergency break end 2024-08-21 until now in my personal lock loss account. The first lockloss from NLN tagged "IMC" was 2024-09-13 1410300819 (plot here), then got more and more frequent: 2024-09-19, 2024-09-21, then almost every day since the 2024-09-23.
Oli found that we've ben seeing PSL/FSS glitches since before June 80520 (they didn't check before that). The first lockloss tagged FFS_OSCLATION (where FSS_FAST_MON >3 in the 5 seconds before lock loss) was Tuesday September 17th 80366.
Keita and Sheila discussed that on September 12th the IMC gain distribution was changed by 7dB (same output but gain moved from input of board to output): 79998. We think this shouldn't effect the PSL but it could possibly have exasperated the PSL glitching issues. We could try to revert this change if the PSL power chassis swap doesn't help.
On Wednesday 9th Oct the IMC gain redistribution was reverted: 80566. It seems like this change has helped reduce the locklosses from a glitching PSL/FSS but hasn't solved it completely.