ryan.crouch@LIGO.ORG - posted 10:54, Saturday 12 October 2024 - last comment - 20:35, Saturday 12 October 2024(80632)
Lockloss 17:52 UTC (20:46 lock)

Lockloss at 17:52 UTC, potentially from a 6.2 from Costa Rica.

Relocking is going to be tough, given the rising microseism (getting above 90th percentile), and the winds creeping up.

Comments related to this report
ryan.crouch@LIGO.ORG - 13:43, Saturday 12 October 2024 (80634)CDS

20:37 UTC lost it at LOWNOISE_LENGTH_CONTROL, the IMC and ASC_AS lost lock 150ms inbetween. 1Hz oscillation in MICH

ryan.short@LIGO.ORG - 16:04, Saturday 12 October 2024 (80636)

Towards the end of TRANSITION_FROM_ETMX, a 1Hz oscillation started building up mainly in DHARD_P before we lost lock right when getting to LOWNOISE_LENGTH_CONTROL

Images attached to this comment
ryan.short@LIGO.ORG - 20:35, Saturday 12 October 2024 (80637)

H1 finally back to observing after 9.5 hours of downtime fighting several earthquakes and high microseism.

Displaying report 1-1 of 1.