RyanC, Camilla, Vicky
I noticed that the SQZer wasn't locking from NUC33 this morning when I first adjusted the OPO temperature. The OPO kept dropping when the FC trys to lock IR, there was a SQZ ISS saturated notification on DIAG_MAIN. I looked through the alogs and wikis on this. I investigated the checks that RyanS went through last night in alog80639 to no avail, I also tried setting FC1 & 2 back to their spots from the last time we locked the SQZer using OSEMs which didn't help either. I ended up contacting Camilla, where we:
H1:SQZ-FC_TRANS_C_LF_OUTPUT improved form 75 to 120.def PMC_PZT_OK(): return 5 < ezca['SQZ-PMC_PZT_VOLTS'] < 95 and everything worked fine. Simular issue to what Ryan Short had in https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=80490