Reports until 11:37, Sunday 13 October 2024
H1 SQZ
ryan.crouch@LIGO.ORG - posted 11:37, Sunday 13 October 2024 - last comment - 13:45, Sunday 13 October 2024(80646)
SQZ issues this morning

RyanC, Camilla, Vicky

I noticed that the SQZer wasn't locking from NUC33 this morning when I first adjusted the OPO temperature. The OPO kept dropping when the FC trys to lock IR, there was a SQZ ISS saturated notification on DIAG_MAIN. I looked through the alogs and wikis on this. I investigated the checks that RyanS went through last night in alog80639 to no avail, I also tried setting FC1 & 2 back to their spots from the last time we locked the SQZer using OSEMs which didn't help either. I ended up contacting Camilla, where we:

Comments related to this report
ryan.crouch@LIGO.ORG - 13:45, Sunday 13 October 2024 (80648)
Images attached to this comment