Reports until 15:41, Tuesday 15 October 2024
X1 SUS
ibrahim.abouelfettouh@LIGO.ORG - posted 15:41, Tuesday 15 October 2024 - last comment - 10:33, Thursday 17 October 2024(80689)
BBSS Transfer Function and Drift Update

Ibrahim, Oli

Below are updates and promising findings concerning the most recent BBSS LHO Top Mass -4mm BP Adjustments to tackle the F1 Drift issue summarized in alog 80577.

On Friday 10/11, Oli P and I moved the blade positions (mm BP Units) to:

Front Left: Side: 0.02, Top: -4.03 Back Left: Side: -0.03, Top -3.90 Front Right: Side: 0.02, -3.91 Back Right: Side: -0.05, -3.95 Avg: Side: -0.01 Height: -3.95

Find:

The good news is that with these 4.5 days of Data, we see no sign of F1 Drift.

We will post another alog with TF to model comparisons as we find which model d1 parameter fits these -4mm BP positions best.

Images attached to this report
Non-image files attached to this report
Comments related to this report
timothy.ohanlon@LIGO.ORG - 07:16, Wednesday 16 October 2024 (80703)

That's good news! What is the configuration for the addable masses on the top mass for both the bottom and top plate? 

ibrahim.abouelfettouh@LIGO.ORG - 12:15, Wednesday 16 October 2024 (80712)
The Addable Masses on the top plate were redistributed to the Front (top). 150g and 150g as shown in the attached image.

No change to the bottom plate. We did not change the total mass.
Images attached to this comment
ibrahim.abouelfettouh@LIGO.ORG - 10:33, Thursday 17 October 2024 (80726)

Adding this Pitch Plot (which still shows no drift!) to give a measure of how much the diurnal moves day-to-day. Plot attached shows a max of 31.8 cts trough to peak max.

This is such that future drift measurements (e.g. at LLO) can try new configurations quickly and measure the prevailing drift without getting caught in the daily pitch breathing error.

 

 

Images attached to this comment