thomas.shaffer@LIGO.ORG - posted 00:10, Wednesday 16 October 2024 - last comment - 04:17, Wednesday 16 October 2024(80700)
Ops Owl Update

Been trying to get the violins down for the past 2 hours and made barely any progress. Many of the problem modes on ITMX just didn't seem to respond positively to any gains that have worked in the past. We just lost lock, so I'll try some damping on RF and see if that can somehow help.

Comments related to this report
thomas.shaffer@LIGO.ORG - 03:07, Wednesday 16 October 2024 (80701)

After losing lock a few times while damping, I think I've finally found a combo that kinda works. While waiting in RF I would request the violin gaurdian to go to DAMPING_ON_SIMPLE, then change the ITMX mode 3 gain down from -40 and increase as needed, and change the ETMY mode 1 to +90 and with a gain of -0.2 as teh google doc says. This worked well and damped most of the problematic modes. I still had issues with ITMX mode 3 & 13 though. This is the limiting factor right now. These two modes just won't go down at any reasonable pace.

Just lost lock again. The lock losses have been from small earthquakes, and other reasons that I haven't figured out.

thomas.shaffer@LIGO.ORG - 04:17, Wednesday 16 October 2024 (80702)

Damped in RF for a while and was able to get ITMX modes to what I thought were reasonable levels, when we transitioned to DC there were still saturations going on, so I tried damping further there but we lost lock. Each time they ring back up and I have to start almost from scratch. I thought that there must be an incorrect setting or filter on ITMX, but I haven't found anything. At this point I'm beginning to think there might be something else wrong, but I have no idea where to keep looking right now since things seem to somewhat work while damping the violins.