Displaying report 1-1 of 1.
Reports until 16:30, Friday 18 October 2024
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:30, Friday 18 October 2024 (80752)
OPS Day Shift Summary

TITLE: 10/18 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY:

IFO is in NLN and OBSERVING as of 21:19 UTC.

A few significant events:

PSL Maintenance: Sheila and Vicky re-reduced the NPRO current - alog 80746

Fast Shutter Weirdness: Upon reaching NLN, we could not go into observing because the shutter guardian was registering the shutter as closed/not working. After the initial shock, it was determined through trends that this was just a Guardian thing, rather than yet another broken toaster. alog 80749

EY Timing Glitch: Dave noticed an 800ns timing glitch with no consequences - alog 80742

Locklosses: Two PSL FSS Related Locklosses: alog 80748 and alog 80741. Both before the PSL change and none thereafter.

SQZ Adjustments: Went out of observing briefly to optimize SQZ angle and temp.

PIs: PI 24 and 31 rung up heavily today but were successfully and automatically damped, causing no locklosses.

LOG:

Start Time System Name Location Lazer_Haz Task Time End
16:36 SAFE HAZARD LVEA YES !!!!!LVEA IS LASER HAZARD!!!! 03:16
19:57 PSL Vicky, Sheila LVEA Y NPRO Current Revert 20:20
22:34 VAC Janos FCES Mechanical Room N Compressor Check 23:25
Displaying report 1-1 of 1.