Displaying report 1-1 of 1.
Reports until 13:05, Monday 21 October 2024
H1 ISC (Lockloss, PSL)
ibrahim.abouelfettouh@LIGO.ORG - posted 13:05, Monday 21 October 2024 - last comment - 18:19, Monday 21 October 2024(80798)
Lockloss 19:55 UTC

Lockloss most likely due to PSL FSS Glitch. ASC and IMC lost lock within 63ms of one another, which is suspect. However, it seems AS_A lost lock first, so it might not be FSS related - unsure. Plots below.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 13:33, Monday 21 October 2024 (80799)Lockloss

No FSS tag on the lockloss tool

ryan.short@LIGO.ORG - 18:19, Monday 21 October 2024 (80809)OpsInfo

Tagging OpsInfo: I've added an ndscope template to the lockloss select tool that provides some good channels to look at to help determine if it was caused by the PSL glitches. Running it for this lockloss, I would say this does not look like an "FSS glitch" lockloss (see attached).

Images attached to this comment