Displaying report 1-1 of 1.
Reports until 16:18, Thursday 10 October 2013
H1 ISC
alexan.staley@LIGO.ORG - posted 16:18, Thursday 10 October 2013 (8080)
MCL PZT Controller

MCL C02219: EX Table PZT 2, NB85-AR10 (to be replaced)

MCL C02218: EX Table PZT1, ND2-AR10-ISS

  Input (V) Sensor (V) HV/10 (V)
x 0 0 -0.06
y 0 0 -1.97
x 10 10 9
y 10 10 9.89
x -10 -2.7 -1.78
y -10 -3 -1.79

MCL C02718: EY Table PZT 2

  Input (V) Sensor (V) HV/10 (V)
x 0 0 -0.06
y 0 0 -1.97
x 10 10 11.08
y 10 10 10.22
x -10 -2.5 -1.705
y -10 -4.9 -1.653

MACL C02722: EY Table PZT 1 (test previously and seen similar results to MCL C02718)

The three PZT's (two on EY, one on EX) have a range from 0 to 10V. Another 0 to 10 V will be placed on EX. Important note: the controller must be hooked up to it's respective PZT in order to be properly tested.