PR3 damping contributions to DARM

J. Freed, S. Dwyer

 

Yesterday we did damping loop injections on all 6 BOSEMs on the PR3 M1. PR3 shows quite alot of coupling in the 10-25Hz range. This is a continuation of the work done previously for ITMX, ITMY, and PR2

As some signals were quite strong, instead of gain of 750, gains of 300 and 600 were collected (300 is labled as low_noise). Also, this time injections were performed in diaggui instead of awggui

The plots, code, and flagged frequencies are located at /ligo/home/joshua.freed/20241021/scrpts. While the diaggui files are at /ligo/home/joshua.freed/20241021/data. This time, 600 gain data was also saved as a reference in the diaggui files (see below), saved in 20241021_H1SUSPR3_M1_OSEMNoise_T3.xml

pr3.png Shows all results for PR3 with the top half being at 300 gain and the bottom being at 600 gain. All sensors showed strong coupling in 10-25Hz range at 600 gain. [LF, RT, T2, T3] showed strong coupling in 10-25Hz range at 300 gain. [SD, T1] instead showed some coupling in the 46-48Hz range at 300 gain. I am unsure if this is signifficant or another noise source while the test was performed.

DiagguiInj.png Shows the set up for the injections in Diaggui. The ramp up and down values in measurment tab were also set to 5sec
 
GPS Times of injections (reference number in diaggui files)
Background time:      1413584423 (ref0 DARM, ref1 LF_out, ref2 RT_out, ref3 SD_out, ref4 T1_out, ref5 T2_out, ref6 T3_out)
LF(low_noise) time:    1413585519
LF time:                        1413585643 (ref7 DARM, ref8 LF_out)
RT(low_noise) time:    1413585954
RT time:                        1413586086 (ref9 DARM, ref10 RT_out)
SD(low_noise) time:   1413586349
SD time:                       1413586510 (ref11 DARM, ref12 SD_out)
T1(low_noise) time:    1413586757
T1 time:                        1413586873 (ref13 DARM, ref14 T1_out)
T2(low_noise) time:    1413587139
T2 time:                        1413587245 (ref15 DARM, ref16 T2_out)
T3(low_noise) time:    1413587436
T3 time:                        1413587545 (ref17 DARM, ref18 T3_out)

 

 