Displaying report 1-1 of 1.
Reports until 16:39, Tuesday 22 October 2024
H1 TCS
camilla.compton@LIGO.ORG - posted 16:39, Tuesday 22 October 2024 - last comment - 09:43, Wednesday 23 October 2024(80812)
CO2Y Laser Swap

TJ, Camilla, Fil. 

WP12142,  Table layout: T1200007. Swapping because current CO2Y laser was at the end of it's gas life and slowly deteriorating, details in 79560. Prep done in 80679.

Removed: Access 50LT 20510-20816D, which was re-gassed in 2016 and installed in October 2022 65264.
Installed: Access 50LT 20706-21015 /alt link, which was re-gassed in the last month.

Still to do:

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 09:43, Wednesday 23 October 2024 (80834)

TJ, Camilla

Checked the pointing of CO2Y on ITMY using the annular mask and HWS, as in 68391 by injecting ~2W of CO2 after we could see the beam was mostly centered. The IFO beam is ~centered on the origin cross, checked in plot from 80148.

HWS plot is attached as the CO2 was heating and cooling ITMY, we decided that this was well aligned enough not to pico. It's possible these a little more beam in the lower left of the HWS image but the FLIR images yesterday looks the same as before the swap.

Images attached to this comment
Displaying report 1-1 of 1.