LHO Continuity Test of Fast Shutter Air Cable

WP 12159

High voltage disabled. Control Chassis powered off. Cable to chamber disconnected at rack/chassis.

Continuity test of pins:

  1. Pins A & C tied together
  2. Pins B & D tied together
  3. Pins E & F tied together

All pins and shell open to chamber ground.

Comments related to this report
filiberto.clara@LIGO.ORG - 13:15, Wednesday 23 October 2024 (80849)

Next test:

Driver chassis power off, HV off, cable to chamber connected:

The DB25 controls cable was disconnected on the rear of the driver chassis. Cable comes form CER slow controls. Pin 14 has about 100 ohms to chamber ground.