Reports until 12:26, Wednesday 23 October 2024
H1 CDS (DAQ, SYS)
jeffrey.kissel@LIGO.ORG - posted 12:26, Wednesday 23 October 2024 - last comment - 15:58, Thursday 24 October 2024(80846)
CDS Front-Ends are Mostly at RCG 5.1.4; Where to Find RCG Release Notes
J. Kissel echoing E. Dohmen

Just a bit of useful info from E.J. that I think others might be interested in (and giving myself bread crumbs to find the info in the future):

- The PRODUCTION (H1 included) systems are only at 5.1.4 with no plans on upgrading soon. 

- h1susetmx computer, however is at a prototype version of 5.3.0 in order to support LGIO DAC testing (see LHO:79735)

- One can find the running release notes for modern versions (since RCG 2.0) of the RCG at
https://git.ligo.org/cds/software/advligorts/-/blob/master/NEWS?ref_type=heads
Comments related to this report
david.barker@LIGO.ORG - 14:28, Wednesday 23 October 2024 (80850)

This information is also shown on the CDS overview. Models with a purple mark are built using a non-production RCG version. Clicking on the purple mark opens the RCG MEDM for more details.

Please see alog-78920 for details.

brian.lantz@LIGO.ORG - 09:43, Thursday 24 October 2024 (80858)

FWIW - The Stanford test stands are running RCG 5.3 to allow development and testing of the SPI readout code.

erik.vonreis@LIGO.ORG - 15:58, Thursday 24 October 2024 (80864)

There's also some release notes here:

https://dcc.ligo.org/T1700552