Displaying report 1-1 of 1.
Reports until 08:10, Tuesday 29 October 2024
H1 SUS
oli.patane@LIGO.ORG - posted 08:10, Tuesday 29 October 2024 (80911)
TMTS TF check to verify corrected Coil Driver Strength

In 80171, we noted that the incorrect coil driver strength had been in use for getting the calibration in plotTMTS_dtttfs.m. We corrected this value and last week I was able to take transfer function measurements of the TMTs, which we wanted to take just so we could verify that the updated calibration was more accurate to the models, and also just because it had been four and two years since taking measurements for TMSX and TMSY, respectively.

I've attached the pdfs for their individual analyses (TMSX, TMSY), as well as comparisons between the most recent and previous measurements (TMSX, TMSY). The corrected coil driver strengths do shift the measurement traces up closer to the model traces.

Non-image files attached to this report