I have updated the plotallhlts_tfs_M1.m matlab script to allow the user to plot any potential cross-coupling. There is a newly-added boolean near the top called plotOffDiagonalTFs that can be set depending on whether you want to see the off-diagonal plots or not, and there is also a coupling matrix that can be changed depending on what coupling you want to see. The plots get appended to the end of the regular transfer function pdf file, allhltss_*_ALL_TFs.pdf. Attached is an example of how the cross-coupling plots are laid out. The script has been committed to svn as part of revision 12063.