oli.patane@LIGO.ORG - posted 16:42, Thursday 31 October 2024 (80982)
Ops Day Shift End

TITLE: 10/31 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Currently relocking and at DARM_TO_RF. Spent most of the day unlocked, with two locklosses and multiple hours of downtime while trying to figure out the FSS issues. Relocking since that work finished has gone great so far.
A couple minutes after Jenne and Betsy left the PSL laser room(and maybe also antetroom), we did notice the FSS PZT have the huge oscillations for about two minutes(attachment), similar to those we had been seeing on the backup FSS boxes(probably alog to come). Jenne is not sure what that means in the case of this FSS box, but mentioned that it might have been due to turning off the air conditioning or something else related to them being in there.
LOG:

14:30 Close to end of an initial alignment
14:40 Initial alignment done, relocking
15:25 NOMINAL_LOW_NOISE
15:32 Observing

16:01 Dropping Observing for Commissioning

16:22 Lockloss
    17:17 Took to DOWN and started manual initial alignment due to DRMI being bad and PRMI ASC having trouble
    17:31 manual IA done, started relocking
18:13 NOMINAL_LOW_NOISE

18:35 Lockloss from little earthquake+low CARM gain actuation range
    18:38 Started an initial alignment
    FSS unlocked due to measurement cable being plugged in and was unlocked for an hour
    20:05 FSS relocked, started manual initial alignment for PRC, MICH, SRC
    20:21 Left manual initial alignment for IDLE for PSL FSS box swap
    22:59 PSL incursion done, started an initial alignment
    23:17 Initial alignment done, relocking                                                                                                                                                                                                                                               

Start Time System Name Location Lazer_Haz Task Time End
15:28 FAC Karen OptLab/VacPrep n Tech clean 15:50
16:02 PEM Robert LVEA n Setting up for injections 16:20
16:28 PSL Sheila, Vicky LVEA n Setting up for measurements 16:37
17:01 FAC Karen WoodShop n Tech clean 18:02
18:41 PSL Jenne, Sheila, Vicky LVEA n Connecting cable for FSS transfer functions 18:59
20:02 ISI Jim HAM Shack n Move measurement equipment 20:40
20:36 PSL Betsy, Jenne PSL Encl y(local) Swapping FSS box 22:58
20:39 EE Fil, Rick, Daniel, Fernando CER, LVEA n Turning off HV, looking at PSL rack layout (Fil out 21:13), Rick out 22:12
20:59   Richard LVEA n Looking at PSL light pipes 21:15
21:03 FAC Tyler CER n Investigating burning smell 21:07
21:16 EE Fil LVEA n Looking at SQZ racks 21:56
21:22 EE Rick, Fil CER n Turn HV back on 21:25
21:48 EE Fil LVEA n Taking other FSS box out to PSL 22:29
21:58 EE Marc LVEA n Helping with FSS box 22:14
21:58   Rick CER n Turning off high voltage 22:12
22:16 EE Rick, Marc CER n Turning HV back on 22:21
22:35 EE Rick, Fil CER n Turnign off HV 22:54
Images attached to this report