Reports until 16:34, Sunday 03 November 2024
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 16:34, Sunday 03 November 2024 - last comment - 10:25, Monday 04 November 2024(81037)
Looking at locklosses from over the weekend

 Most of the locklosses over this weekend have the IMC tag and those do show the IMC losing lock at the same time as AS_A, but since I don't have any further insight into those, I wanted to point out a few locklosses where the causes are different from what we've been seeing lately.

2024-11-02 04:17UTC

2024-11-02 17:13 UTC

2024-11-02 18:38:30.844238 UTC

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 10:25, Monday 04 November 2024 (81046)

I checked during some normal NLN times and the H1:PSL-ISS_AOM_DRIVER_MON_OUT_DQ channel does not normally drop below 0.31 while we are in NLN (plot). In Oli's times before in lockloss, it drops to 0.28 when we loose lock. Maybe we can edit the PSL glitch scripts 80902 to check this channel.