Some clues regarding disturbance degrading Crab pulsar sensitivity

As reported in 79897, a bump has been apparent in the H1 spectrum in the vicinity of the Crab pulsar for much of O4b.

So far, it looks like:

The attached plots are all generated from Fscan weekly and monthly averaged data. The feature can be seen most clearly in these long-duration spectra.

There is a git issue tracking the problem here, with some additional discussion history and more plots: https://git.ligo.org/detchar/detchar-requests/-/issues/273