Displaying report 1-1 of 1.
Reports until 16:22, Thursday 07 November 2024
H1 SUS
anthony.sanchez@LIGO.ORG - posted 16:22, Thursday 07 November 2024 (81132)
Weekly In-Lock SUS Charge Measurement

FAMIS 28376

ls /opt/rtcds/userapps/release/sus/common/scripts/quad/InLockChargeMeasurements/rec_LHO  -lt | head -n 6
total 511
-rw-r--r-- 1 test_user          controls   160 Oct  8 07:58 ETMX_12_Hz_1412434733.txt
-rw-r--r-- 1 test_user          controls   160 Oct  8 07:50 ETMY_12_Hz_1412434262.txt
-rw-r--r-- 1 test_user          controls   160 Oct  8 07:50 ITMY_15_Hz_1412434244.txt
-rw-r--r-- 1 test_user          controls   160 Oct  8 07:50 ITMX_13_Hz_1412434243.txt
-rw-r--r-- 1 test_user          controls   160 Sep 24 07:58 ETMX_12_Hz_1411225133.txt

The latest measurements were already documented in this alog, and the measurements were not run this week.

Displaying report 1-1 of 1.