Displaying report 1-1 of 1.
Reports until 15:14, Friday 08 November 2024
H1 General (Lockloss, PSL)
anthony.sanchez@LIGO.ORG - posted 15:14, Friday 08 November 2024 - last comment - 19:43, Friday 08 November 2024(81152)
Friday Eve shift Early start

TITLE: 11/08 Eve Shift: 0030-0600 UTC (1430-2200 PST), all times posted in UTC
STATE of H1: Observing at 161Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 1mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.43 μm/s
QUICK SUMMARY:
H1 has been locked for 1 hour.
All systems running well.
Lockloss potentially Caused by PSL issues

The first Channels that show motion is the H1:PSL-FSS_FAST_MON_OUT_DQ

Relocking now, Currently @  Engage soft loops.

 

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 19:43, Friday 08 November 2024 (81157)

Trends on this lockloss are coincident with PSL FSS / ISS / TPD glitches - so I think the PSL tag is appropriate here.

We added MC2_TRANS to the scope (top right subplot), and it shows power changes earlier than IMC_TRANS_{IN1_OUT}_DQ channels.

I think this means that IMC power changes do happen within 1 ms of FSS glitches starting, which wasn't clear from the IMC_TRANS channel we've been using (where the 16k IN1_DQ and 2k OUT_DQ channels both showed >ms delays of IMC power changing).

Images attached to this comment
Displaying report 1-1 of 1.