Reports until 15:30, Tuesday 15 October 2013
H1 AOS
jason.oberling@LIGO.ORG - posted 15:30, Tuesday 15 October 2013 - last comment - 14:05, Wednesday 16 October 2013(8116)
Initial ETMx Alignment Numbers
Initial ETMx alignment numbers before any adjustments made (pitch/yaw numbers are approximate due to LAC interference from the ERM reflection):
  • Longitudinal: -14.0 mm (unchanged)
  • Lateral: -3.1 mm (East)
  • Vertical: +1.04 mm (high)
  • Yaw: ~425 µrad CW
  • Pitch: ~2.25 mrad down
Comments related to this report
jason.oberling@LIGO.ORG - 14:05, Wednesday 16 October 2013 (8127)
Disregard the above pitch/yaw numbers, I did not realize the ETMx was still lightly on stops.  See alog 8126 for accurate pitch/yaw numbers.  The above position numbers remain unchanged after freeing the suspension.