anthony.sanchez@LIGO.ORG - posted 08:03, Saturday 09 November 2024 - last comment - 16:50, Saturday 09 November 2024(81161)
Saturday Ops Day Shift Start

TITLE: 11/09 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 4mph Gusts, 3mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.40 μm/s
QUICK SUMMARY:
Walking in I was greeted with ISC_LOCK in Engage Soft Loops.
Unfortunately we lost lock at Transition_From_ ETMX  and again at DRMI
Starting an Initial_Alignment

Notes on OWL:
IFO called Ryan early in the morning https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=81160.
Over the Owl Shift there were a number of locks and locklosses, I'll follow up with a comment to this alog with more information about each lockloss.

Comments related to this report
anthony.sanchez@LIGO.ORG - 11:19, Saturday 09 November 2024 (81164)Lockloss

Relocking notes:
Relocking has been difficult as it seems the IMC is unlocking at random intervals.
Called Dr. Capote, for back up.
Holding in IDLE for the IMC to become stable.
IMC has been stable for 5 minutes now.
Starting the Initial_Alignment.



 

anthony.sanchez@LIGO.ORG - 16:50, Saturday 09 November 2024 (81166)Lockloss, PSL

I wanted to get to this earlier this morning but a break down of the locklosses last night:

Lockloss ID 1415198551 https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1415198551
Multiple - ScreenShots - attached -for this Lockloss - including one of the PSL-FSS_FAST_MON Zoomed way in , but all the normal ones are there too.
This has that weird PSL/ IMC issue and was even tagged so on the Lockloss page.

Lockloss ID 1415193456 An unknown Lockloss. Which this does have some PSL-FSS_FAST_MON motion before hand but it doesnt seem as pronounced. Also it's not tagged as an IMC via the Lockloss page.
Multiple - ScreenShots - attached -for this Lockloss , Just to deliniate from other locklosses 

 

Lockloss ID 1415184378 was an earthquake I'm not attaching screenshots for this one.
 

Lockloss ID 1415176335 https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1415184378
Multiple - ScreenShots - attached -for this Lockloss - including one of the PSL-FSS_FAST_MON Zoomed way in , but all the normal ones are there too.
This has that weird PSL/ IMC issue and was even tagged so on the Lockloss page just like the first one.