Lockloss seemingly PSL caused judging from IMC and ASC-A signals losing lock within 10ms (attached). About a 700ms after the glitching started, we lost lock. Interestingly, IMC is not glitching for minutes post-LL as it usually does, with IMC locking and staying locked in the new acquisition.
Spoke way way (way) too soon. The glitch has been happening since the lockloss, which is much longer than usual. I've been staying in DOWN and attempting to lock if we pass 5 mins without glitching, which happened twice only to lose lock to it around DRMI or FIND_IR...
Watching the channels closely for when it stops so I can actually lock. The screenshot shows that the longest time without glitching since LL is that first 19 mins.