Reports until 17:13, Tuesday 15 October 2013
X1 DTS
david.barker@LIGO.ORG - posted 17:13, Tuesday 15 October 2013 - last comment - 19:55, Tuesday 15 October 2013(8120)
mx_stream reconfiguration, DAQ data sending to card0 on x1dc0 only

To reproduce the 2.8 problems seen on H1 today, we reconfigured the /etc/init.d/mx_stream startup script to only use card0 10GE card on x1dc0. Front ends still have unique end-point identifiers (line number in rtsystab file), but are now not split over the two 10GE cards. Once this was done the DAQ data problem seen on H1 was reproduced on the DTS.

Comments related to this report
keith.thorne@LIGO.ORG - 19:55, Tuesday 15 October 2013 (8122)
What appears to be similar corruption was seen LLO DTS using RCG 2.8 with only two front-ends (but no 10G cards on data concentrator x2daqdc). Behavior is the same whether one or two 1G input are used on x2daqdc.