Suspicious ETMX transition locklosses

We seem to be having lots of locklosses during the transition from ETMX/lownoise ESD ETMX guardian states. With Camilla's help, I looked through the lockloss tool to see if these are related to the IMC locklosses or not. "TRANSITION_FROM_ETMX" and "LOWNOISE_ESD_ETMX" are states 557 and 558 respectively.

For reference, transition from ETMX is the state where DARM control is shifted to IX and EY, and the ETMX bias voltage is ramped to our desired value. Then control is handed back over the EX. Then, in lownoise ESD, some low pass is engaged and the feedback to IX and EY is disengaged.

In total since the start of O4b (April 10), there have been 26 locklosses from "transition from ETMX"

From the start of O4b (April 10) to now, there have been 22 locklosses from "lownoise ESD ETMX"

Trending the microseismic channels, the microseism increases seems to correspond with the worsening of this lockloss rate for lownoise ESD ETMX. I think, when correcting for the IMC locklosses, the transition from ETMX lockloss rate is about the same. However, the lownoise ESD ETMX lockloss rate has increased significantly.

Comments related to this report
elenna.capote@LIGO.ORG - 15:39, Monday 11 November 2024 (81202)

Here is a look at what these locklosses actually look like.

I trended the various ETMX, ETMY and ITMX suspension channels during these transitions. The first two attachments here show a side by side set of scopes, with the left showing a successful transition from Nov 10, and the right showing a failed transition from Nov 9. It appears that in both cases, the ITMX L3 drive has a ~1 Hz oscillation that grows in magnitude until the transition. Both the good and bad times show a separate oscillation right at the transition. This occurs right at the end of state 557, so the locklosses within 1 or 2 seconds of state 558 likely are resulting from whatever the of the steps in state 557 do. The second screenshot zooms in to highlight that the successful transition has a different oscillation that rings down, whereas the unsuccessful transition fails right where this second ring up occurs.

I grabbed a quick trend of the microseism, and it looks like the ground motion approximately doubled around Sept 20 (third screenshot). I grabbed a couple of recent successful and unsuccessful transitions since Sept 20, and they all show similar behavior. A successful transition from Sept 19 (fourth attachment) does not show the first 1 Hz ring up, just the second fast ring down after the transition.

I tried to look back at a time before the DAC change at ETMX, but I am having trouble getting any data that isn't minute trend. I will keep trying for earlier times, but this already indicates an instability in this transition that our long ramp times are not avoiding.

Images attached to this comment
elenna.capote@LIGO.ORG - 16:51, Monday 11 November 2024 (81208)

Thanks to some help from Erik and Jonathan, I was able to trend raw data from Nov 2023 (hint: use nds2). Around Nov 8 2023, the microseism was elevated, ~ 300 counts average on the H1:ISI-GND_STS_ITMY_Z_BLRMS_100M_300M channel, compared to ~400 counts average this weekend. The attached scope compares the transition in Nov 8 2023 (left) versus this weekend Nov 10 (right). One major difference here is that we now have a new DARM offloading scheme. A year ago, it appears that this transition also involves some instability causing some oscillation in ETMX L3, but the instability now creates a larger disturbance that rings down in both the ITMX L3 and ETMX L3 channels.

Images attached to this comment
elenna.capote@LIGO.ORG - 18:11, Monday 11 November 2024 (81213)

Final thoughts for today:

  • the lockloss occurs within 1-2 seconds of when the ramp down of IX L3 and the ramp up of EX L3 occurs, so it seems like the issue here is within the L3 control
  • we have had instability issues with this transition back in March when we were commissioning it, which did include a 1 Hz instability
  • The growing oscillation before the transition is about 1 Hz, whereas the larger oscillation that can coincide with the lockloss is around 3 Hz.
  • Although the microseism is higher, this overall RMS on each suspension stage hasn't changed appreciably since April (see attachment). However, this plot compares NLN times. It's seems like the switchover itself is unstable, which is maybe too fast to compare
  • The switchover is between IX/EY control which appears to be on the "old" configuration and the EX "new" configuration, so even if each individual configuration is stable, maybe a combo of them is unstable.
Images attached to this comment
elenna.capote@LIGO.ORG - 10:58, Tuesday 12 November 2024 (81224)OpsInfo

Sheila and I looked a look at these plots again. It appears that the 3 Hz oscillation has the potential to saturate L3, which might be causing the lockloss. The ringup repeatedly occurs within the first two seconds of the gain ramp, which is set to a 10 second ramp. We decided to shorten this ramp to 2 seconds. I created a new variable on line 5377 in the ISC guardian called "etmx_ramp" and set that to 2. The ramps from the EY/IX to EX L3 control are now set to this value, as well as the timer. If this is bad, this ramp variable can be changed back.